The Livable Housing Design Standard sets the minimum access features for new houses under the National Construction Code (NCC), and has applied in Victoria since 1 May 2024 and in Queensland since 1 October 2023. It calls for a step-free entry, wider doors and corridors, an accessible entry-level toilet, a hobless shower and reinforced bathroom walls.
Below are the numbers for each feature, the state rules, exemptions for difficult sites, renovations and what the Standard changes in a design.
ROMAAC Group designs and builds custom homes in Victoria and Queensland, and on a custom design these rules are best settled at the first sketch, because they depend on floor levels, the route to the front door and the bathroom layout.
Building rules in this guide were checked against the NCC, the Building and Plumbing Commission and the Queensland Government on 24 November 2026. They are general information, so confirm how they apply to your design with your building surveyor in Victoria or building certifier in Queensland.
The Livable Housing Design Standard, officially the ABCB Standard for Livable Housing Design, is a technical standard written by the Australian Building Codes Board (ABCB). Part H8 of NCC Volume Two requires every new Class 1a dwelling to comply with it, and Part G7 of Volume One applies it inside apartments.
Class 1a covers a detached house, and an attached house such as a townhouse, terrace or villa unit with a fire-resisting wall between it and its neighbour. Part H8 gives the purpose plainly: housing that meets the needs of the community, including older people and people with a mobility-related disability.
The ABCB calls the Standard "a set of minimum necessary provisions, rather than as an exemplar of best practice". It is not meant for designing specialist accommodation, and it does not aim to match AS 1428.1, the Australian Standard on design for access and mobility.
The Standard first appeared in NCC 2022. NCC 2025 calls up version 1.4, released on 1 May 2026, and the ABCB lists that version's changes as a referenced document update and minor corrections.
The Livable Housing Design Guidelines, sometimes spelt "liveable", are the voluntary scheme the Standard grew out of. Livable Housing Australia first published them with graded levels such as Silver and Gold, and the ABCB adapted the Standard from the Silver level of the fourth edition, published in 2017.
The two do not match exactly, because the ABCB adjusted some provisions to turn a voluntary guideline into a regulation. It has also published a non-mandatory version of the Standard based on the Gold level, for owners who want a higher level of livability.
The current version of the Standard has six parts, each with a measurable minimum: access to the dwelling, the entrance, internal doors and corridors, the toilet, the shower and wall reinforcement. The table sets them out with the clause each one comes from.
| Requirement | Minimum for a new house | Clause |
|---|---|---|
| Step-free access path | No steps; gradient no steeper than 1:14 and crossfall no steeper than 1:40; at least 1000 mm wide; from the street entry, a garage or carport, or a car space kept for the household | 1.1 |
| Ramps on the path | No more than 9 m of ramp in total at 1:14, or 15 m at 1:20; a landing at least 1200 mm long at each end; one step ramp allowed, up to 190 mm high, 1:10 and 1900 mm long | 1.1 |
| Car space on the path | At least one space 3200 mm wide x 5400 mm long, no steeper than 1:33 for bitumen or 1:40 for other surfaces | 1.2 |
| Entrance door | At least one with an 820 mm clear opening | 2.1 |
| Entrance threshold | Level; a rounded or bevelled lip up to 5 mm; or a ramped threshold no steeper than 1:8 within the depth of the door jamb | 2.2 |
| Landing outside the entrance | 1200 mm x 1200 mm, level or no steeper than 1:40 for drainage | 2.3 |
| Internal doors | 820 mm clear opening to habitable rooms and the laundry on the ground or entry level, and to the compliant toilet and shower room | 3.1 |
| Corridors | At least 1000 mm between the finished wall surfaces | 3.3 |
| Toilet | One on the ground or entry level, with clear space of 1200 mm x 900 mm in front of the pan, outside the door swing | 4.1, 4.2 |
| Shower | At least one hobless and step-free, with a lip of up to 5 mm allowed | 5.2 |
| Wall reinforcement | Beside the compliant toilet and shower, and any non-freestanding bath in that shower room: 12 mm structural plywood, 25 mm timber or steel noggings to the NASH Standard; not needed in concrete or masonry walls | 6.1, 6.2 |

The path must reach an entrance door without steps, from the street boundary, a garage or carport, or a car space kept for the household. It can arrive through a connecting door from an attached garage instead of the front door, as long as that door meets the entrance rules. Any gate along the path needs the same 820 mm opening as a door.
One entrance door needs an 820 mm clear opening, which the ABCB says a single swinging door can generally achieve with an 870 mm door leaf. Outside it, a landing of 1200 mm by 1200 mm must be level, or fall no more steeply than 1:40 for drainage.
Because a level threshold lets water reach the door, the Standard also sets the weatherproofing: a channel drain across the entrance on concrete or another impermeable surface, drainage under a deck, or a roof over at least 1200 mm by 1200 mm outside the door.
In the version called up by NCC 2025, a raised sill is allowed where a level threshold cannot meet the NCC's weatherproofing rules. It can have no upstand over 15 mm within the sill, and its edge must sit within 5 mm of the surface beside it.
On the ground or entry level, doors into habitable rooms and the laundry need an 820 mm clear opening. In NCC language, habitable rooms include bedrooms, living and dining areas, the kitchen, a study and similar rooms. The doors to the compliant toilet and shower room, and from an attached garage on the step-free path, need the same opening.
Corridors leading to those doors must be at least 1000 mm wide between the finished wall surfaces, and skirtings, architraves and power points are ignored in that measurement.
At least one sanitary compartment (any room with a toilet, whether a bathroom, ensuite or powder room) must be on the ground or entry level. In front of the pan it needs a clear space of 1200 mm by 900 mm, kept clear of the door swing whether the door opens in, opens out or slides.
In a separate WC, the walls either side of the pan must be at least 900 mm apart. In any room with that toilet, a basin or vanity must sit at least 450 mm from the pan's centreline.
At least one shower must be hobless and step-free: no raised kerb (a hob) at the entry and no step down into it. The ABCB names both because a level shower can still have a hob, and a sunken one has no hob but still has a step. A lip of up to 5 mm is allowed, and this shower can be on any level.
The walls beside the compliant toilet and shower, and around a bath in that shower room unless it is freestanding, must be reinforced so grab rails can be fixed later without stripping the linings. Grab rails themselves do not have to be installed when the house is built.
The accepted materials are 12 mm structural grade plywood or similar, timber framing at least 25 mm thick, or light gauge steel noggings or plates to the NASH Standard. Concrete or masonry walls that can already carry a rail need nothing extra.
Every new house in both states must meet the Standard: in Victoria since 1 May 2024, and in Queensland since 1 October 2023. What now differs is the edition of the NCC each state uses and the state rules layered on top.
| Item | Victoria | Queensland |
|---|---|---|
| New houses must comply since | 1 May 2024 | 1 October 2023 |
| NCC edition in force | NCC 2025 from 1 May 2026, for projects whose design work started after that date | NCC 2022 until 30 April 2027; NCC 2025 from 1 May 2027 |
| State law that gives it effect | Building Act 1993 and Building Regulations 2018 | Building Act 1975, with variations in the Queensland Development Code, including QDC MP 4.5 |
| Renovations and extensions | Regulation 233 of the Building Regulations 2018 | QDC MP 4.5 and the Modern Homes Home Renovation Guideline |
| Extra state options | None: the NCC exemptions apply, and Victoria has no variation to Part H8 | Narrow-lot exemption to 30 September 2029; ramp-ready option for elevated homes; a step-free pathway using AS 1428.1 |
| Who checks the design | The relevant building surveyor, before issuing the building permit | The building certifier, who assesses and approves the plans |
Victoria adopted NCC 2025 on 1 May 2026. The Building and Plumbing Commission (BPC) explains how NCC 2025 commenced in Victoria: its updates apply only to projects that had not started design work before that date, and a project already in design can keep the standards in place when work began.
Under either edition, your building surveyor checks the design against the Victorian regulations and the NCC before issuing the building permit.
Queensland gives the NCC legal effect through the Building Act 1975, varies it through the Queensland Development Code, and stays on NCC 2022 until 30 April 2027. Its own code part, QDC MP 4.5 (Livable dwellings and grading to floor wastes), adds options the national code does not have, and a building certifier assesses and approves the plans.
The Queensland Government's Livable Housing Design Standard page lists changes to QDC MP 4.5 that took effect on 14 August 2026:
Only the step-free path can be exempted, and only when two things are true at once. There must be no step-free route from a garage, carport or car space kept for the household, and at least one of these site conditions must apply:
Part H8's explanatory note stresses that both conditions must apply, and it names flood levels, alpine sites and homes built directly over a garage among the reasons a floor can sit too high.
An exempt home still has to meet everything else in the Standard, so the 820 mm doors, corridors, toilet, shower and reinforced walls all stay. The landing outside the entrance also falls away with the path.

Queensland adds time-limited exemptions for certain narrow lots and small pre-built houses through QDC MP 4.5, so check whether a narrow block actually qualifies rather than assuming it does. In either state, ask your building surveyor or certifier to confirm an exemption before the design relies on it.
In Victoria it depends on how much of the house the work touches. Regulation 233 of the Building Regulations 2018 gives the relevant building surveyor discretion, and the BPC's guidance on livable housing design requirements explains how it works for houses:
The BPC adds that a surveyor may consider it unreasonable to widen existing hallways or upgrade an existing toilet that the work does not touch. Where the work does affect the relevant toilet, that part is expected to comply.
In Queensland, QDC MP 4.5 clarifies how the Standard applies to repairs, maintenance and major renovations. The Queensland Government's Modern Homes Home Renovation Guideline covers alterations, additions and relocated homes, and your building certifier confirms what applies to the specific work.
Most of what the Standard asks for is settled at concept design, before the drawings are detailed, because it depends on levels, the route to the door and the bathroom layout. These are the decisions it brings forward:
Queensland's QDC MP 4.5 has its own version of the two-storey option: the accessible toilet can sit on a level with a habitable room where the entry level has none.

Owners who plan to stay in a home for decades often design past the minimum, and the ABCB's voluntary Gold-based version is one benchmark. Common additions in a custom design are an entry-level bedroom near the compliant bathroom, the compliant shower on that same level, doorways wider than 820 mm and space kept for a future lift.
These choices cost least when they are written into the brief. Designing only for the household you have today tends to mean structural work when the household changes. Ageing parents moving in is the familiar case, and it is why a multigenerational home is often planned around a ground-floor suite and a step-free route from the car.
Where someone in the household already uses a wheelchair or walking frame, an occupational therapist or access consultant can set dimensions around that person rather than around the code minimum.
The fourth edition of the Guidelines, published in 2017, sets out three voluntary levels. Silver covers seven core elements and is the basis of the mandatory Standard, while Gold asks for more generous dimensions for most of them and adds elements such as the kitchen and bedroom. Platinum goes further on most core elements and covers all 15 elements, including the living room and flooring, to suit ageing in place and people with higher mobility needs.
The ABCB adapted the Gold level into its Beyond Minimum Voluntary Standard, noting that it is not an exact copy. It is not mandatory under the NCC, but a home designed to it still meets the NCC by the Deemed-to-Satisfy route (the ready-made way to comply), because its provisions exceed the Standard's minimums. The table compares the two using the ABCB's figures.
| Feature | The Standard (NCC minimum) | ABCB voluntary standard (Gold-based) |
|---|---|---|
| Entrance and internal doorways | 820 mm clear opening | 850 mm clear opening |
| Corridors | 1000 mm wide | 1200 mm wide |
| Clear space in front of the toilet | 900 mm wide x 1200 mm long | 1200 mm x 1200 mm |
| Shower | Hobless and step-free, on any level | Hobless and step-free on the ground or entry level, at least 900 mm x 900 mm, with 1200 mm x 1200 mm clear beside it |
| Kitchen and laundry | Not covered | 1200 mm clear in front of benches and appliances |
| Bedroom | Not covered | A room of at least 10 square metres on the ground or entry level |
| Internal stairs | Not covered | Flights at least 1000 mm wide, no winders (tapered treads at a turn) or spiral stairs, beside a wall that can take a chairlift |
Yes. A knockdown rebuild creates a new house, so it must meet the Standard like any other new Class 1a dwelling, with the same exemptions for the step-free path on a difficult site. In Victoria the NCC edition depends on when design work started, and in Queensland NCC 2022 applies until 30 April 2027.
Yes. Following the Standard is the Deemed-to-Satisfy route, the NCC's ready-made way to comply, but a designer can instead propose a Performance Solution that meets Performance Requirement H8P1, for the surveyor or certifier to assess. In Victoria, the Building Appeals Board can also be asked to modify a requirement, and the BPC advises asking the building surveyor first.
The Standard is easiest to meet when the entry level, the path from the street or garage and the bathrooms are fixed before design development. On a steep, narrow or raised site, ask your building surveyor or certifier early whether an exemption applies. ROMAAC can talk through the levels, entry and bathrooms of your new home from the first concept.